Example use cases · Ecliptica®

Case studies

Three example use cases of synthetic data generated with Ecliptica®: dissolution profiles, reducing animal use, and real-world data for external control arms.

Example Use Case 1

Synthetic Data for Dissolution Profiles

1. What is dissolution?

A tablet must release drug into solution before the drug can be absorbed.

  1. Tablet / dosage unit

    A physical oral dosage unit enters the dissolution vessel.

  2. Drug is released

    The formulation breaks down and releases the active ingredient.

  3. Drug dissolves

    We measure the percentage dissolved at several time points.

  4. Drug can be absorbed

    Dissolution is an in-vitro indicator of release behaviour—not the same as clinical absorption.

In this example, the experimental unit is one dosage unit (e.g. one tablet), and each unit has a complete dissolution trajectory over time. Unit of synthesis = the whole profile, not an isolated time-point measurement.
Line chart: B. Augmented Reference vs Augmented Test, Test vs Reference comparison after augmentation. Dissolution F (%) from about 37 to 92 over 1 to 10 hours; Test starts lower, crosses near 3 to 4 hours and ends higher.

Example of a dissolution profile:

Test is lower early, similar around 3-4 h, and higher later. The more similar the profiles over time, the more likely the Test (new generic) is similar to the reference (established drug).

2. Why compare Reference and Test products?

The question is simple: do the two products release drug in a sufficiently similar way?

  1. Reference product

    The comparator product. Its mean percentage dissolved is measured over time.

  2. Test product

    The product being compared with the Reference under the same experimental conditions.

  3. Compare the profiles

    The similarity factor f₂ summarises the distance between the two mean dissolution curves.

f₂ is a measure of similarity: 0 = no similarity ; 100 = perfect similarity

f₂ = 100identical mean profiles
f₂ ≥ 50conventional similarity criterion when applicable
Observed here:63.6comfortably above 50

Regulatory context

ICH M9 specifies at least 12 Test and 12 Reference units for each comparative dissolution profile. EMA guidance likewise uses at least 12 individual values at each time point for f₂-based comparison.

Thumbnail of the Augmented Reference vs Augmented Test dissolution chart

3. Would the results have changed if we had used fewer units (material) ?

Same-size synthetic generation tested fidelity before scaling up.

63.586Observed Ref vs Test f₂
N=12/group
xxxxxSame-size synthetic f₂
N=12/group Synthetic
65.201Augmented 4x synthetic f₂
N=24/group

What this showed

  • The synthetic data reproduced both formulation trajectories and the Test-vs-Reference relationship: 63.586 vs xxxxx.
  • The augmented synthetic data also showed that if the experiment were larger, the results would be the same
  • The augmented experiment tells us that increasing the experiment size above N=12 per group would not have changed the conclusion: similarity could have been established in 12, even if we had planned for N=24

Why not simply test 48?

More physical testing means more vessel/instrument time, analytical work, sample handling, documentation and material consumption.

Material can matter

In early formulation development, API, prototypes, pilot batches or specialised excipients may be limited.

Important

Synthetic units do NOT replace the required physical units. They are model-generated virtual profiles for exploration and simulation.

Line chart: B. Augmented Reference vs Augmented Test, Test vs Reference comparison after augmentation.
Core finding4× synthetic augmentation preserved the dissolution profiles and the Test-vs-Reference conclusion.

What ICH M9 expects

Comparative dissolution under defined conditions, including at least pH 1.2, 4.5 and 6.8 and at least 12 Test and Reference units per profile.

4. How close were the augmented mean profiles?

Real-minus-Augmented differences stayed small across all time points.

Line chart: D. Real Test vs Augmented Test, Test profile fidelity after augmentation. The Real Test and Augmented Test curves lie almost exactly on top of each other from 1 to 10 hours.

Near zero = close mean-profile agreement

The correct value proposition

Synthetic augmentation is valuable for simulation, robustness, sensitivity and design exploration - not for pretending the physical sample size increased.

5. Bootstrap vs synthetic-generative simulation

Both methods reached the same decision in every simulated study.

63.217Bootstrap mean f₂
64.939Synthetic mean f₂
2.003Bootstrap SD
2.878Synthetic SD
100%Both P(f₂≥50)

Bootstrap 95% simulation range

59.113 to 67.080
Minimum = 55.371

Synthetic 95% simulation range

59.765 to 70.964
Minimum = 55.255

Across all 10,000 simulated studies, none fell below the conventional f₂ = 50 threshold.

6. What did synthetic simulation add beyond bootstrap?

It explored a broader model-based range while preserving the lower-tail decision.

Bootstrap range width = 7.97
Synthetic range width = 11.20

Potential value: generative simulation can explore plausible profiles beyond literal resampling of the 12 observed units.

Interpret carefully

The synthetic distribution was broader (SD 2.878 vs 2.003). This argues against simple over-smoothing, but does NOT prove the synthetic uncertainty is “more correct”.

Most decision-relevant result

The lower 2.5th percentiles were very similar: 59.113 bootstrap vs 59.765 synthetic—and both remained well above 50.

7. What are the practical benefits of synthetic data here?

The value is not simply “more tablets”; it is a validated environment for exploring uncertainty before spending more experimental resources.

Robustness

Estimate how often the similarity conclusion would recur across many plausible 12-vs-12 experiments.

Sensitivity / stress testing

Ask how changes in early or late dissolution, variability or trajectory structure affect f₂.

Study-design exploration

Compare virtual sample sizes or development strategies before deciding whether more physical experiments are worthwhile.

Sparse development data

Explore plausible behaviour when prototypes, API or pilot-batch material are limited.

Data sharing & methods

Use privacy/commercially safer model-generated data for programming, training, collaboration and method development—after utility/risk validation.

Decision support

A borderline f₂ result can be converted from one point estimate into a model-based picture of decision stability.

Synthetic augmentation supplements experimental evidence; it does not manufacture new empirical evidence.

8. What we should NOT claim

Clear boundaries make the use case more credible.

Do not sayWe tested 48 tablets.
Say insteadWe generated 48 virtual dosage-unit profiles per formulation.
Do not saySynthetic data increased the experimental N four-fold.
Say insteadThe physical N remained 12+12; the virtual population was expanded for simulation.

9. Take-home message

What this experiment supports today.

A small physical dissolution experiment can be used to train and validate a generative model that creates a larger population of plausible virtual dosage-unit profiles without materially changing the original scientific conclusion.
63.6Observed f₂
xxxxxSame size synthetic f₂
65.14× augmented f₂

The benefit is not “more experimental tablets.”

The benefit is a validated simulation environment for robustness, sensitivity and development decisions.